+86-571-88550927
Nizki svinčeni manometer video

Nizki svinčeni manometer

Nizek svinčni manometer
Accuracy: ±(3-2-3 percent FS), Size: 1½" or 2"
Omočeni deli: fosforjev bron, Bourdonova cev in medenina ali celotno nerjaveče jeklo.
kontaktirajte merilnike za več podrobnosti in natančno ceno.

Opis

Nizek svinčni manometer

Pakiranje Dostava:

Pakiranje: ločena škatla za papir na enoto.

Vrsta pakiranja: poliesterska vrečka plus papirna škatla, kartonska škatla, paleta.

Teža kartona: 20-25 kg

Dobavni rok: 15-30 dni

Opisi:

Accuracy: ±(3-2-3 percent FS)
Size: 1½" or 2"
Omočeni deli: fosforjev bron, Bourdonova cev in medenina
Razponi: tlak - 0 do 300 psi (če so potrebni drugi razponi, se obrnite na službo za pomoč strankam)

LOW LEAD PRESSURE GAUGE


thread size

O nas:

factory figure 1

factory figure 2

Več izdelkov

relatedproducts

Komunikacije:

communications

Potrdila

pressure gauge certificate R

Proizvodnja in pregled

pressure gauge factory 4

production process

Raven natančnosti
1. Ocena točnosti manometra odraža natančnost prikazane vrednosti, ki je blizu realni vrednosti v primerjavi med preizkušenim in preciznim manometrom. Enaka je odstotku razmerja med absolutno vrednostjo največje osnovne napake in zgornjo mejo merjenja, ki se določi glede na napako, ustvarjeno pri kalibraciji.
2. China's general industrial pressure gauges are divided into four accuracy levels, which comply with the allowable error of the pressure gauge in the verification regulation of spring tube general pressure gauge, pressure vacuum gauge and vacuum gauge (jjg52-1999). The four accuracy levels are: Level 1, level 1.6, level 2.5 and level 4. The allowable error (calculated as a percentage of the upper limit of measurement) is ± 1 percent , ± 1.6 percent , ± 2.5 percent and ± 4 percent respectively.
3. China's new verification regulation of digital pressure gauge was published and implemented in 2005, which is in line with jjg875-2005 verification regulation of digital pressure gauge. The accuracy of pressure is specified as ± 0.01 percent , ± 0.02 percent , ± 0.05 percent , ± 0.1 percent , ± 0.2 percent , ± 0.5 percent , ± 1.0 percent and ± 1.6 percent respectively.
4. Metoda razumne izbire stopnje točnosti merilnika tlaka mora temeljiti na zahtevah proizvodnega procesa, gospodarnosti in praktičnosti, metode zaznavanja itd., stopnja točnosti pa se izbere glede na dovoljeno napako, ki jo zahteva najmanjša vrednost. izmerjenega tlaka.

Pakiranje in pošiljanje:

packing process


contact us 1

Priljubljena oznake: nizko svinčeni manometer, Kitajska, dobavitelji, proizvajalci, tovarne, po meri, veleprodaja, poceni

Pošlji povpraševanje

(0/10)

clearall